The effects of injectable platelet-rich fibrin on implant stability

Tarih

2022

Yazar

Güvenç, Serhat
Durmuşlar, Cenk
Ballı, Umut

Üst veri

Tüm öğe kaydını göster

Künye

Güvenç S, Durmuşlar C, Ballı U. The effects of injectable platelet-rich fibrin on implant stability. International Journal of Oral & Maxillofacial Implants (2022): 37(6), 1145-1150.

Özet

Purpose: To investigate the effects of injectable platelet-rich fibrin (i-PRF) on implant stability. Materials and Methods: A total of 40 implants (BEGO Semados RS/RSX implants, BEGO Implant System) were surgically placed in 15 patients between the ages of 25 and 67 years who had mandibular edentulous areas. After the implant sockets were prepared with the appropriate protocol, i-PRF was applied to the implant surface and socket with the help of a 5-cc sterile syringe in the study group, and implants were placed without i-PRF in the control group. In the research process, the resonance frequency analysis (RFA) method was used to measure implant stability. The implant stability quotient (ISQ) values were determined during the time of the operation and at the first, second, and fourth weeks. Results: The results obtained after the stability measurement periods showed that the decrease in the mean ISQ values in the control group was statistically significant in the first week. Evaluations made in the following weeks were not statistically significant. The study group showed an increase in ISQ values during the measurement periods, and the increases in the second and fourth weeks were statistically significant. Conclusion: I-PRF had positive effects on early implant stability, and i-PRF can be safely used in dental implant surgery and promotes bone healing around dental implants.

Kaynak

International Journal of Oral & Maxillofacial Implants

Cilt

37

Sayı

6

Bağlantı

http://quintpub.com/journals/omi/abstract.php?iss2_id=1839&article_id=22769
https://hdl.handle.net/20.500.12780/663

Koleksiyonlar

  • Makale Koleksiyonu [120]
  • WoS İndeksli Yayınlar Koleksiyonu [268]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Kent

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber || Yönerge || Kütüphane || İstanbul Kent Üniversitesi || OAI-PMH ||

İstanbul Kent Üniversitesi, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
İstanbul Kent Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Kent:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.