The effects of caries removal techniques on volume-loss percentage and microtensile bond strength

dc.contributor.authorKanar, Özlem
dc.contributor.authorTağtekin, Dilek
dc.contributor.authorKorkut, Bora
dc.contributor.authorYanıkoğlu, Funda
dc.date.accessioned2026-03-04T12:15:09Z
dc.date.issued2025
dc.departmentİstanbul Kent Üniversitesi, Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.description.abstractPurpose This study aimed to calculate the volume loss percentages (VLP) regarding the ICDAS II system and various caries removal techniques (CRT) and to assess the microtensile bond strength (µTBS) in terms of VLP following CRT. Materials and Methods Three-dimensional data of human extracted molars were acquired with an extraoral dental scanner (Ineos x5, Dentsply Sirona) before and after the caries removal. Each ICDAS score group (0,3,4 and 5) was divided into four subgroups according to the CRT: stainless steel bur (Group S), ceramic bur (Group C), tungsten carbide bur (TCB) and air abrasion (AA) with bioactive-glass (Group TB), and TCB and AA with Al2O3 (Group TA). Pre and post-caries removal data were overlaid in a 3D modeling software and were volumetrically measured (n=10). Following the restoration, samples were prepared with non-trimming technique and subjected to microtensile testing. Results ICDAS II scores were found related the VLP (p< 0.001) and the µTBS (p<0.001). CRT was not effective on VLP (p=0.110), whereas CRT type was significant on µTBS (p<0.001). In Group TA, a strong negative correlation was observed between the µTBS and the VLP for ICDAS 5 score (r=-0.919; p=0.027). Conclusion ICDAS II can provide a preliminary indication for the amount of VLP and reduction in µTBS following caries removal. The use of 29 µm Al2O3 with air abrasion in deep caries removal may improve µTBS while potentially reducing the VLP.
dc.identifier.citationKANAR, Ö., TAGTEKIN, D., KORKUT, B., YANIKOGLU, F. (2025). The effects of caries removal techniques on volume-loss percentage and microtensile bond strength*. European oral research (Online) , 59(2), 129 - 137.
dc.identifier.doi10.26650/eor.20241391161
dc.identifier.endpage137
dc.identifier.issn2651-2823
dc.identifier.issue2
dc.identifier.orcid0000-0002-9701-5860
dc.identifier.orcid0000-0002-2675-1764
dc.identifier.orcid0000-0001-6360-9436
dc.identifier.orcid0000-0001-5708-1030
dc.identifier.scopus2-s2.0-105008576385
dc.identifier.scopusqualityQ3
dc.identifier.startpage129
dc.identifier.trdizinid1348530
dc.identifier.urihttps://iupress.istanbul.edu.tr/journal/eor/article/the-effects-of-caries-removal-techniques-on-volume-loss-percentage-and-microtensile-bond-strength
dc.identifier.urihttps://hdl.handle.net/20.500.12780/1406
dc.identifier.volume59
dc.indekslendigikaynakTR-Dizin
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherIstanbul University Press
dc.relation.ispartofEuropean Oral Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAir abrasion
dc.subjectCaries removal technique
dc.subjectDental scanner
dc.subjectMicrotensile bond strength
dc.subjectVolume loss
dc.titleThe effects of caries removal techniques on volume-loss percentage and microtensile bond strength
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
yanikoglu.funda
Boyut:
678.43 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: