A comprehensive assessment of radiation protection practices in dental clinics for patients administered 99mTc MDP undergoing bone scintigraphy

dc.contributor.authorAkdoğan, Emine Tuna
dc.contributor.authorDemir, Mustafa
dc.date.accessioned2026-04-06T12:08:55Z
dc.date.issued2026
dc.departmentİstanbul Kent Üniversitesi, Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.description.abstractObjective: This study aimed to determine the potential radiation doses to which dentists may be exposed when examining or performing interventional procedures on patients who have undergone technetium-99m methylene diphosphonate (⁹⁹ᵐTc-MDP) bone scintigraphy, primarily performed for the evaluation of bone malignancies. In addition, it sought to identify appropriate radiation protection measures from the perspective of dental practitioners. Materials and Methods: A total of 53 patients who underwent bone scintigraphy were included in this study. Each patient received an average of 925 megabecquerels (MBq) of ⁹⁹ᵐTc-MDP as a radiopharmaceutical. Two hours after administration, bone scintigraphy imaging was performed. Between 0.5 and 3 hours after imaging, radiation dose rate measurements were obtained from the head–neck, thoracic, and abdominopelvic regions using a radiation detector positioned at distances of 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm. Results: The mean dose rates measured from the thoracic region at 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm were 144.3 ± 36.9, 107.2 ± 16.9, 73.5 ± 13.8, 42.7 ± 10.0, and 12.5 ± 8.7 µSv/h, respectively. It was estimated that the daily exposure dose to a dentist would be below 4 µSv after approximately 10.4 hours of patient contact. Conclusion: If a patient who has undergone bone scintigraphy visits a dentist for examination or treatment 3 hours after imaging, the dentist’s radiation exposure would remain below the annual dose limit of 1 mSv. However, it was also determined that the 4 µSv/day exposure threshold could be reached after approximately 10.4 hours of close contact.
dc.identifier.citationAkdoğan ET, Demir M (March 1, 2026) A Comprehensive Assessment of Radiation Protection Practices in Dental Clinics for Patients Administered 99mTc Mdp Undergoing Bone Scintigraphy. Meandros Medical And Dental Journal 27 1 116–123.
dc.identifier.doi10.69601/meandrosmdj.1809940
dc.identifier.endpage123
dc.identifier.issn2149-9063
dc.identifier.issue1
dc.identifier.orcid0000-0001-8608-0862
dc.identifier.orcid0000-0002-9813-1628
dc.identifier.startpage116
dc.identifier.urihttps://dergipark.org.tr/en/pub/meandrosmdj/article/1809940
dc.identifier.urihttps://izlik.org/JA59MF99HR
dc.identifier.urihttps://hdl.handle.net/20.500.12780/1432
dc.identifier.volume27
dc.identifier.wos001724797700009
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherAydın Adnan Menderes University
dc.relation.ispartofMeandros Medical And Dental Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBone scintigraphy
dc.subjectRadiation dose
dc.subjectExposure
dc.subjectDentist
dc.subjectDental treatment
dc.titleA comprehensive assessment of radiation protection practices in dental clinics for patients administered 99mTc MDP undergoing bone scintigraphy
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
akdogan,eminetuna.pdf
Boyut:
559.1 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: