Determination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC-MS/MS

dc.contributor.authorGürsoy, Selim
dc.contributor.authorBodur, Süleyman
dc.contributor.authorAtakol, Arda
dc.contributor.authorBakırdere, Sezgin
dc.date.accessioned2026-04-27T13:43:51Z
dc.date.issued2026
dc.departmentİstanbul Kent Üniversitesi, Fakülteler, Eczacılık Fakültesi, Temel Eczacılık Bilimleri Bölümü
dc.description.abstractHydrocortisone and cortisone are clinically informative steroids whose joint measurement at low concentrations is essential for ratio-reliable interpretation. A spraying-assisted fine droplet formation liquid-phase microextraction (SA-FDF-LPME) was combined with liquid chromatography–tandem mass spectrometry (LC–MS/MS) for simultaneous quantitation in saliva-type matrices as part of a method-development study. Method parameters were optimized to secure chromatographic resolution, stable ion ratios, and high sensitivity. Under direct injection, LOD/LOQ values were 1.05/3.50 µg kg–1 for cortisone and 0.80/2.68 µg kg–1 for hydrocortisone, with dynamic ranges of 3.65–150.77 and 2.59–268.45 µg kg–1, respectively. With SA-FDF-LPME coupled to LC–MS/MS, LOD/LOQ were 0.0164/0.0547 µg kg–1 for cortisone and 0.0734/0.245 µg kg–1 for hydrocortisone, and dynamic ranges were 0.049–4.983 and 0.210–5.50 µg kg–1, respectively. Accuracy was established by pre-extraction spiking at different concentrations in two artificial saliva formulations. Using external-standard calibration, recoveries were 105.3–129.4%/110.4–141.1% for cortisone and 110.0–134.9%/94.1–142.8% for hydrocortisone; with matrix-matched calibration, recoveries were 80.3–103.2%/98.1–117.8% for cortisone and 79.8–105.7%/97.3–114.0% for hydrocortisone. The developed SA-FDF-LPME–LC–MS/MS method enables sensitive, accurate, and simultaneous quantification of hydrocortisone and cortisone at saliva-relevant concentrations and offers a practical platform for selective bioanalysis of related small molecules.
dc.identifier.citationGürsoy, S., Bodur, S., Atakol, A. et al. Determination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC–MS/MS. Sci Rep 16, 7064 (2026).
dc.identifier.doi10.1038/s41598-026-38457-z
dc.identifier.issn2045-2322
dc.identifier.issue1
dc.identifier.orcid0000-0003-3233-0728
dc.identifier.orcid0000-0002-2994-9047
dc.identifier.orcid0000-0003-3090-6324
dc.identifier.orcid0000-0001-9746-3682
dc.identifier.pmid41634132
dc.identifier.urihttps://www.nature.com/articles/s41598-026-38457-z
dc.identifier.urihttps://doi.org/10.1038/s41598-026-38457-z
dc.identifier.urihttps://pubmed.ncbi.nlm.nih.gov/41634132/
dc.identifier.urihttps://hdl.handle.net/20.500.12780/1472
dc.identifier.volume16
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer Nature
dc.relation.ispartofScientific Reports
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectArtificial saliva
dc.subjectHydrocortisone
dc.subjectCortisone
dc.subjectSpraying assisted fine droplet formation liquid phase microextraction
dc.subjectTandem mass spectrometry
dc.titleDetermination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC-MS/MS
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
atakol,arda.pdf
Boyut:
2.51 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: