Determination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC-MS/MS
| dc.contributor.author | Gürsoy, Selim | |
| dc.contributor.author | Bodur, Süleyman | |
| dc.contributor.author | Atakol, Arda | |
| dc.contributor.author | Bakırdere, Sezgin | |
| dc.date.accessioned | 2026-04-27T13:43:51Z | |
| dc.date.issued | 2026 | |
| dc.department | İstanbul Kent Üniversitesi, Fakülteler, Eczacılık Fakültesi, Temel Eczacılık Bilimleri Bölümü | |
| dc.description.abstract | Hydrocortisone and cortisone are clinically informative steroids whose joint measurement at low concentrations is essential for ratio-reliable interpretation. A spraying-assisted fine droplet formation liquid-phase microextraction (SA-FDF-LPME) was combined with liquid chromatography–tandem mass spectrometry (LC–MS/MS) for simultaneous quantitation in saliva-type matrices as part of a method-development study. Method parameters were optimized to secure chromatographic resolution, stable ion ratios, and high sensitivity. Under direct injection, LOD/LOQ values were 1.05/3.50 µg kg–1 for cortisone and 0.80/2.68 µg kg–1 for hydrocortisone, with dynamic ranges of 3.65–150.77 and 2.59–268.45 µg kg–1, respectively. With SA-FDF-LPME coupled to LC–MS/MS, LOD/LOQ were 0.0164/0.0547 µg kg–1 for cortisone and 0.0734/0.245 µg kg–1 for hydrocortisone, and dynamic ranges were 0.049–4.983 and 0.210–5.50 µg kg–1, respectively. Accuracy was established by pre-extraction spiking at different concentrations in two artificial saliva formulations. Using external-standard calibration, recoveries were 105.3–129.4%/110.4–141.1% for cortisone and 110.0–134.9%/94.1–142.8% for hydrocortisone; with matrix-matched calibration, recoveries were 80.3–103.2%/98.1–117.8% for cortisone and 79.8–105.7%/97.3–114.0% for hydrocortisone. The developed SA-FDF-LPME–LC–MS/MS method enables sensitive, accurate, and simultaneous quantification of hydrocortisone and cortisone at saliva-relevant concentrations and offers a practical platform for selective bioanalysis of related small molecules. | |
| dc.identifier.citation | Gürsoy, S., Bodur, S., Atakol, A. et al. Determination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC–MS/MS. Sci Rep 16, 7064 (2026). | |
| dc.identifier.doi | 10.1038/s41598-026-38457-z | |
| dc.identifier.issn | 2045-2322 | |
| dc.identifier.issue | 1 | |
| dc.identifier.orcid | 0000-0003-3233-0728 | |
| dc.identifier.orcid | 0000-0002-2994-9047 | |
| dc.identifier.orcid | 0000-0003-3090-6324 | |
| dc.identifier.orcid | 0000-0001-9746-3682 | |
| dc.identifier.pmid | 41634132 | |
| dc.identifier.uri | https://www.nature.com/articles/s41598-026-38457-z | |
| dc.identifier.uri | https://doi.org/10.1038/s41598-026-38457-z | |
| dc.identifier.uri | https://pubmed.ncbi.nlm.nih.gov/41634132/ | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12780/1472 | |
| dc.identifier.volume | 16 | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Springer Nature | |
| dc.relation.ispartof | Scientific Reports | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Artificial saliva | |
| dc.subject | Hydrocortisone | |
| dc.subject | Cortisone | |
| dc.subject | Spraying assisted fine droplet formation liquid phase microextraction | |
| dc.subject | Tandem mass spectrometry | |
| dc.title | Determination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC-MS/MS | |
| dc.type | Article |










