Basit öğe kaydını göster

dc.contributor.authorŞeker, Merve
dc.contributor.authorAlkan, Elif
dc.contributor.authorKorkut, Bora
dc.contributor.authorIlgın, Can
dc.contributor.authorTağtekin, Dilek
dc.contributor.authorYanıkoğlu, Funda
dc.date.accessioned2021-06-07T12:09:44Z
dc.date.available2021-06-07T12:09:44Z
dc.date.issued2020en_US
dc.identifier.citationŞeker M., Alkan E.,Korkut B., Ilgın C., Tağtekin D., Yanıkoğlu F. Assessment of efficiency of two different intraoral scanners in determination of caries related volume loss. Prevent from Caries Symposium lll, International, Online, Abst. No.37,13-14, November 2020.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12780/340
dc.description.abstractAbstract Aim: Digital impressions taken with intraoral scanners are applications with proven validity. The data obtained with these systems can be virtually evaluated in three dimensions (3D). The aim of the study was to compare the cavity volume data obtained with two different intraoral scanners. Materials and Methods: The extracted lower molar teeth were examined according to the ICDAS II and divided into 4 groups(n=10). The teeth with ICDAS 3, 4, and 5 scores included only on the occlusal surface to provide standardization. The teeth with ICDAS 0 score were included in the study as the control group. All samples were scanned with Cerec Omnicam (Sirona,Bensheim,Germany) and iTero Element Flex (Align Techology,CA,USA), and initial images were saved as “.stl” format. The caries-infected tissues in teeth with ICDAS 3, 4, and 5 scores removed using a #14 diamond round bur for enamel and a #14 ceramic round bur for dentine (Cerabur,Comet,Germany) regarding the minimally invasive cavity principles. The final images of the teeth were taken with scanners, the data was loaded into Meshmixer 3.5 (Autodesk) 3D modeling software, and volumetric assessments were performed. The data were evaluated statistically with Mann Whitney U and Spearman’s correlation test. The level of significance was set at a=0.05. Results: Although there was a significant difference between the calculated initial volumes of two scanners for ICDAS 3 group (p=0.005), there was no significant difference for the other groups (p≥0.05). Regarding the comparison of final volumes, a significant difference was found for the ICDAS 5 group (p=0.036), whereas no significant difference was observed for the other groups between the scanners (p≥0.05). The percentage loss of volume between the two scanners was also similar (p≥0.05). Conclusion: The data obtained with Cerec Omnicam and iTero Element Flex are compatible with each other in terms of volumetric assessment and these devices can be used for calculating the cavity volumes. Intraoral scanners can be alternative systems to digital radiography for 3D examinations and calculations with the advantage of not requiring cross-sectional images.en_US
dc.language.isoengen_US
dc.publisherTürkiye Kliniklerien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIntraoral scanneren_US
dc.subjectVolume lossen_US
dc.subjectICDASen_US
dc.subjectMinimally invasive dentistryen_US
dc.subjectCavity preparationen_US
dc.titleAssessment of efficiency of two different intraoral scanners in determination of caries related volume lossen_US
dc.typeconferenceObjecten_US
dc.contributor.departmentİstanbul Kent Üniversitesi, Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorYanıkoğlu, Funda
dc.relation.journalPrevent from Caries Symposium lllen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster