• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Fakülteler
  • Sağlık Bilimleri Fakültesi
  • Fizyoterapi ve Rehabilitasyon Bölümü
  • Makale Koleksiyonu
  • View Item
  •   DSpace Home
  • Fakülteler
  • Sağlık Bilimleri Fakültesi
  • Fizyoterapi ve Rehabilitasyon Bölümü
  • Makale Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Aortic valve function post-replacement of severe aortic stenosis by transcatheter procedure versus surgery: a systematic review and metanalysis

Thumbnail

View/Open

Tam Metin/Full Text (2.548Mb)

Date

2021

Author

Khalil, Charbel Abi
Ignatiuk, Barbara
Erdem, Güliz
Chemaitelly, Hiam
Barilli, Fabio
El-Shazly, Mohamed
Al Suwaidi, Jassim
Aboulsoud, Samar
Kofler, Markus
Stastny, Lukas
Jneid,Hani
Bonaros, Nikolaos

Metadata

Show full item record

Citation

Abi Khalil C, Ignatiuk B, Erdem G, et al. Aortic valve function post-replacement of severe aortic stenosis by transcatheter procedure versus surgery: a systematic review and metanalysis. Sci Rep. 2021;11(1):11975. Published 2021 Jun 7. DOI: 10.1038/s41598-021-91548-x

Abstract

Abstract Transcatheter aortic valve replacement (TAVR) has shown to reduce mortality compared to surgical aortic valve replacement (sAVR). However, it is unknown which procedure is associated with better post-procedural valvular function. We conducted a meta-analysis of randomized clinical trials that compared TAVR to sAVR for at least 2 years. The primary outcome was post-procedural patient-prosthesis-mismatch (PPM). Secondary outcomes were post-procedural and 2-year: effective orifice area (EOA), paravalvular gradient (PVG) and moderate/severe paravalvular leak (PVL). We identified 6 trials with a total of 7022 participants with severe aortic stenosis. TAVR was associated with 37% (95% CI [0.51-0.78) mean RR reduction of post-procedural PPM, a decrease that was not affected by the surgical risk at inclusion, neither by the transcatheter heart valve system. Postprocedural changes in gradient and EOA were also in favor of TAVR as there was a pooled mean difference decrease of 0.56 (95% CI [0.73-0.38]) in gradient and an increase of 0.47 (95% CI [0.38-0.56]) in EOA. Additionally, self-expandable valves were associated with a higher decrease in gradient than balloon ones (beta = 0.38; 95% CI [0.12-0.64]). However, TAVR was associated with a higher risk of moderate/severe PVL (pooled RR: 9.54, 95% CI [5.53-16.46]). All results were sustainable at 2 years.

Source

Scientific Reports

Issue

11

URI

https://doi.org/10.1038/s41598-021-91548-x
https://hdl.handle.net/20.500.12780/469

Collections

  • Makale Koleksiyonu [20]
  • PubMed İndeksli Yayınlar Koleksiyonu [40]
  • Scopus İndeksli Yayınlar Koleksiyonu [73]
  • WoS İndeksli Yayınlar Koleksiyonu [63]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@Kent

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide || Instruction || Library || İstanbul Kent University || OAI-PMH ||

İstanbul Kent University, İstanbul, Turkey
If you find any errors in content, please contact:

Creative Commons License
İstanbul Kent University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Kent:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.