Basit öğe kaydını göster

dc.contributor.authorŞen Baykal, Duygu
dc.date.accessioned2022-07-22T06:31:37Z
dc.date.available2022-07-22T06:31:37Z
dc.date.issued2022en_US
dc.identifier.citationH.O. Tekin, Ghada ALMisned, Y.S. Rammah, Emad M. Ahmed, Fatema T. Ali, Duygu Sen Baykal, Wiam Elshami, Hesham M.H. Zakaly, Shams A.M. Issa, G. Kilic and Antoaneta Ene. (2022) Transmission factors, mechanical, and gamma ray attenuation properties of barium-phosphate-tungsten glasses: Incorporation impact of WO3, Optik. DOI: https://doi.org/10.1016/j.ijleo.2022.169643en_US
dc.identifier.urihttps://doi.org/10.1016/j.ijleo.2022.169643
dc.identifier.urihttps://hdl.handle.net/20.500.12780/555
dc.description.abstractAbstract The purpose of this study is to conduct a thorough examination of the direct and indirect impacts of increasing the quantity of heavy WO3 on gamma-ray transmission, shielding and mechanical properties for some selected barium-phosphate-tungsten glasses. Accordingly, mechanical properties of barium-phosphate-tungsten oxides with chemical formula (50-x)P2O5-50BaO-xWO3 (x = 0.0(S1), 5.0(S2), 10(S3), and 15(S4)) mol% was evaluated using Makishima-Mackenzie model. Next, newly online Phy-X/PSD software and Monte Carlo code were used to examine the gamma radiation characteristics. Gamma-ray transmission factor (TF) values were calculated for S1, S2, S3 and, S4 glass samples for a range of well-known radioisotope energies such for 67Ga, 57Co-57, 111In-111, 133Ba, 201Tl, 99mTc, 51Cr, 131I, 58Co, 137Cs, 60Co. The total packing density (Vt) was enhanced from 0.589 for S1 glass sample (free with WO3) to 0.605 for S4 glass sample (with highest WO3=15 mole%). The total energy dissociation (Gt) of the investigated glasses was increased with increasing the WO3 content: from 51.7 (kJ/cm3) for S1 glasses to 52.45 (kJ/cm3) for S4 glasses. All mechanical moduli were improved with increasing the tungsten trioxide concentration in the studied glasses. Poisson’s ratios were increased with increasing the WO3 concentration. The trend of linear (LAC) and mass attenuation (MAC) coefficients were followed as: (LAC, MAC) S1 < (LAC, MAC) S2 < (LAC, MAC) S3 < (LAC, MAC) S4. Half (HVL) and tenth (TVL) value layers have the trend as (HVL, TVL) S1 > (HVL, TVL) S2 > (HVL, TVL) S3 > (HVL, TVL) S4. The effective atomic number (Zeff) and electron density (Neff) have the same trend. The lowest transmission Factor (TF) values for all glass specimens were examined at a thickness of 3 cm. Furthermore, the S4 sample displayed the least transmission tendency across all glass thicknesses evaluated.en_US
dc.language.isoengen_US
dc.publisherELSEVIERen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBaO- P2O5- WO3 glass systemen_US
dc.subjectMechanical propertiesen_US
dc.subjectRadiation shieldingen_US
dc.subjectMCNPXen_US
dc.titleTransmission factors, mechanical, and gamma ray attenuation properties of barium-phosphate-tungsten glasses: Incorporation impact of WO3en_US
dc.typearticleen_US
dc.contributor.departmentİstanbul Kent Üniversitesi, Fakülteler, Sağlık Bilimleri Fakültesi, Fizyoterapi ve Rehabilitasyon Bölümüen_US
dc.contributor.institutionauthorŞen Baykal, Duygu
dc.relation.journalOpticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster