dc.contributor.author | Kopuz, Dilan | |
dc.contributor.author | Sancak, Elif İlgi | |
dc.contributor.author | Tekçe, Neslihan | |
dc.date.accessioned | 2024-03-22T12:38:22Z | |
dc.date.available | 2024-03-22T12:38:22Z | |
dc.date.issued | 2024 | en_US |
dc.identifier.citation | Kopuz, D; Sancak, Eİ; Tekçe,N. Effect of different decontamination agents on the bond strength of CAD/CAM blocks and repair composite materials (2024). Odovtos International Journal of Dental Sciences, 26(1); 76-85. | en_US |
dc.identifier.issn | 1659-1046 | |
dc.identifier.uri | https://revistas.ucr.ac.cr/index.php/Odontos/article/view/56839 | |
dc.identifier.uri | https://doi.org/10.15517/ijds.2023.56839 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12780/780 | |
dc.description.abstract | The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Universidad de Costa Rica | en_US |
dc.relation.isversionof | 10.15517/ijds.2023.56839 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | CAD/CAM | en_US |
dc.subject | Composite | en_US |
dc.subject | Ivoclean | en_US |
dc.subject | Katana Cleaner | en_US |
dc.subject | Shear bond strength | en_US |
dc.subject | Surface decontamination | en_US |
dc.title | Effect of different decontamination agents on the bond strength of CAD/CAM blocks and repair composite materials | en_US |
dc.type | article | en_US |
dc.contributor.department | İstanbul Kent Üniversitesi, Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü | en_US |
dc.contributor.authorID | https://orcid.org/0000-0003-2979-6068 | en_US |
dc.contributor.institutionauthor | Kopuz, Dilan | |
dc.identifier.volume | 26 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 76 | en_US |
dc.identifier.endpage | 85 | en_US |
dc.relation.journal | Odovtos International Journal of Dental Sciences | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |