Basit öğe kaydını göster

dc.contributor.authorKopuz, Dilan
dc.contributor.authorErçin, Özlem
dc.date.accessioned2024-05-30T10:33:15Z
dc.date.available2024-05-30T10:33:15Z
dc.date.issued2024en_US
dc.identifier.citationKopuz, D.; Erçin, Ö. Ön ısıtma işleminin Bulk-Fill kompozit rezinlerin mikrosızıntı değerleri üzerine etkisi: in vitro çalışma. Turkiye Klinikleri J Dental Sci. 2024;30(2):304-11en_US
dc.identifier.issn2146-8966
dc.identifier.urihttps://www.turkiyeklinikleri.com/article/en-on-isitma-isleminin-bulk-fill-kompozit-rezinlerin-mikrosizinti-degerleri-uzerine-etkisi-in-vitro-calisma-107445.html
dc.identifier.urihttps://hdl.handle.net/20.500.12780/821
dc.description.abstractAmaç: Bu çalışmanın amacı, ön ısıtma işlemi uygulanmış bulk-fill kompozit rezinlerin mikrosızıntı değerlerini karşılaştırmaktır. Gereç ve Yöntemler: Elli adet molar dişin mesiyaline ve distaline 4x3x2 (yükseklik-genişlik-derinlik) boyutlarında Sınıf II kaviteler açıldı. Dört farklı bulk-fill (SonicFill 3, Opus Bulk-Fill APS, Tetric PowerFill, Filtek One Bulk-Fill) ve bir kontrol grubu kompozit rezin (Filtek Z250) ısıtma işlemi uygulanmasına göre; ön ısıtma işlemi (68°C etüvde, 10 dk) ve oda sıcaklığında bekletilmek üzere 2 alt gruba ayrıldı (n=10) ve ardından kaviteler restore edildi. Tüm örnekler termal siklusa (5-55°C, 1.200) tabi tutulduktan sonra 24 saat boyunca %0,5 bazik fuksin çözeltisinde oda sıcaklığında bekletildi. Mikrosızıntının boyutunu ölçmek için dişler, bukkolingual ve meziodistal yönlerde bölündü. Her gruptan ikişer numune taramalı elektron mikroskobu analizi için ayrıldı. Geri kalan örnekler ise mikrosızıntı skor yöntemi kullanılarak değerlendirildi. Veriler Kruskal-Wallis H ve Mann-Whitney U testleri ile istatistiksel olarak analiz edildi (p<0,05). Bulgular: Önceden ısıtma işlemine tabi tutulan kompozit rezinler ile oda sıcaklığındaki kompozit rezinlerin mikrosızıntı değerleri karşılaştırıldığında, Tetric PowerFill, Filtek OneBulk Fill ve Filtek Z250 kompozit rezinlerinde anlamlı farklılıklar görüldü (p<0,05). Isıtılmış kompozit rezinler karşılaştırıldığında ise en yüksek değer Filtek One BulkFill’de görülürken, en düşük değer Tetric PowerFill kompozit rezin grubunda görüldü. Oda sıcaklığındaki kompozit rezinler karşılaştırıldığında ise en yüksek değer Opus Bulk Fill APS’de görülürken, en düşük değer kontrol grubu olan FiltekZ250 kompozit rezin grubunda görüldü. Sonuç: Konvansiyonel tabakalama sistemi ile restore edilen dişlerin, bulk-fill tekniğine göre daha az mikrosızıntı gösterdiği sonucuna ulaşılmaktadır. Test edilen materyallerden Opus Bulk-Fill APS hariç bütün kompozit rezinlerde, ön ısıtma işlemi mikrosızıntı değerlerini negatif yönde etkiledi.en_US
dc.description.abstractObjective: To evaluate the microleakage of preheated bulk-fill resin composites. Material and Methods: Class II cavities with dimensions of 4x3x2 (height-width-depth) were prepared in the mesial and distal parts of a total of 50 intact, caries-free human molar teeth. Four different bulk-fill (SonicFill 3, Opus Bulk-Fill APS, Tetric PowerFill, Filtek One Bulk-Fill) and a resin composite (Filtek Z250) used as a control group. Groups were divided into preheated (kept at 68°C in incubator for 10 mins) and room temperature (n=10 each). All samples were subjected to thermal cycles (5-55°C, 1,200) and kept in 0.5% basic fuchsin solution at room temperature for 24 hours. Teeth were split into buccolingual and mesiodistal directions. SEM analysis was done on two samples per group. The other samples were evaluated using the microleakage score method. Statistical analysis employed Kruskal-Wallis H and Mann-Whitney U tests (p<0,05). Results: When the microleakage values of preheated and room temperature resin com posites were compared, significant differences were observed in Tetric PowerFill, Filtek OneBulk Fill and Filtek Z250 resin composites (p<0.05). When heated resin composites were compared, the highest value was seen in Filtek One BulkFill, while the lowest value was seen in Tetric PowerFill resin composite group. When room temperature resin composites compared, the highest value was seen in Opus Bulk Fill APS, while the lowest value was seen in the FiltekZ250 resin composite group, which was the control group. Conclusion: Teeth restored with the conventional layering system show less microleakage than the bulk-fill technique. Among the tested materials, preheating negatively affected microleakage values in all resin composites except Opus Bulk-Fill APS.en_US
dc.language.isoturen_US
dc.publisherTürkiye Kliniklerien_US
dc.relation.isversionof10.5336/dentalsci.2023-100781en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBileşik rezinleren_US
dc.subjectMikrosızıntıen_US
dc.subjectIsıtmaen_US
dc.subjectBazik fuksinen_US
dc.subjectResin compositesen_US
dc.subjectMicroleakageen_US
dc.subjectHeatingen_US
dc.subjectBasic fuchsinen_US
dc.titleÖn ısıtma işleminin Bulk-Fill kompozit rezinlerin mikrosızıntı değerleri üzerine etkisi: in vitro çalışmaen_US
dc.title.alternativeEffect of preheating process on microleakage values of Bulk-Fill resin composites: an in vitro studyen_US
dc.typearticleen_US
dc.contributor.departmentİstanbul Kent Üniversitesi, Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.authorIDhttps://orcid.org/0000-0003-2979-6068en_US
dc.contributor.authorIDhttps://orcid.org/0000-0003-3379-4567en_US
dc.contributor.institutionauthorKopuz, Dilan
dc.contributor.institutionauthorErçin, Özlem
dc.identifier.volume30en_US
dc.identifier.issue2en_US
dc.identifier.startpage304en_US
dc.identifier.endpage311en_US
dc.relation.journalTürkiye Klinikleri Diş Hekimliği Bilimleri Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster