Basit öğe kaydını göster

dc.contributor.authorKopuz, Dilan
dc.contributor.authorErçin, Özlem
dc.date.accessioned2024-05-30T13:40:23Z
dc.date.available2024-05-30T13:40:23Z
dc.date.issued2024en_US
dc.identifier.citationKopuz D, Erçin Ö. Farklı Solüsyonlarla Renklendirilen Kompozit Rezinlerin Translusensi Parametrelerinin Değerlendirilmesi. ADO Klinik Bilimler Dergisi. 2024;13(2):296-302.en_US
dc.identifier.issn1307-3540
dc.identifier.urihttps://dergipark.org.tr/tr/pub/adoklinikbilimler/issue/84638/1315465
dc.identifier.urihttps://doi.org/10.54617/adoklinikbilimler.1315465
dc.identifier.urihttps://hdl.handle.net/20.500.12780/823
dc.description.abstractAmaç: Bu çalışmanın amacı, farklı solüsyonlarla renklendirilen kompozit rezinlerin translusensi parametrelerini değerlendirmektir. Gereç ve Yöntem: Çalışmada 5 farklı tek renkli kompozit rezin; Clearfil Majesty ES-2 Universal, Omnichroma, Vittra APS Unique, ZenChroma ve Charisma Topaz ONE kullanılmıştır. Her bir kompozit rezinden 28 adet (2 mm kalınlığında-7 mm çapında) disk şeklinde örnekler hazırlanmıştır. Polimerizasyonun tamamlanması için örnekler 24 saat 37 °C distile suda bekletilmiştir. Ardından 4 alt gruba ayrılarak: kahve, distile su, kırmızı şarap ve çay solüsyonlarında renklendirilmiştir (n=7). Örneklerin başlangıç ve 28. gün L, a ve b değerleri, Konica Minolta CM-3600A spektrofotometresi ile siyah ve beyaz arka planlar kullanılarak ölçülmüştür. Ardından, örneklerin translusensi parametreleri (TP) CIEDE2000 formülü ile hesaplanmıştır. Veriler One-Way ANOVA ve Tukey testleri kullanılarak analiz edilmiştir (p<0.05). Bulgular: Örneklerin başlangıç ve renklendirme sonrası değerleri arasında anlamlı farklılıklar bulunurken (p<0.05), sadece distile suda bekletilen örneklerde istatistiksel anlamlılık görülmemiştir (p>0.05). Başlangıçta Omnichroma en yüksek TP değerlerini gösterirken, en düşük TP değerlerini Clearfil Majesty ES-2 Universal göstermiştir. 28 gün renklendirme sonrasında kahve, distile su, kırmızı şarap ve çay solüsyonlarında ZenChroma incelenen materyaller arasında en yüksek TP değerlerini göstermiştir. Sonuç: Çalışmada kullanılan kompozit rezin materyallerinin translusensi değerleri; solüsyonların içeriklerinden, boyayıcı özelliklerinden ve kompozit materyallerin içerik farklılığından önemli ölçüde etkilenmiştir.en_US
dc.description.abstractAim: To evaluate the translucency parameters of resin composites colored with different solutions. Materials and Method: 5 different single-shade resin composites; Clearfil Majesty ES-2 Universal, Omnichroma, Vittra APS Unique, ZenChroma, and Charisma Topaz ONE were used. For each group, 28 samples were prepared (7 mm diameter-2 mm thick). Samples were kept in distilled water at 37 °C for 24 hours to complete polymerization. Then, samples were divided into 4 subgroups: colored in coffee, distilled water, red wine, and tea (n=7). The baseline and 28th day, L, a, and b values were measured with a Konica Minolta CM-3600A spectrophotometer using black-and-white backgrounds. Then, the translucency parameters were calculated with CIEDE2000 formula. Data were analyzed using One-Way ANOVA and Tukey tests (p<0.05). Results: There was a significant difference between the initial and the values after coloration (p<0.05). However, there was no statistically significant difference in the samples kept in distilled water (p>0.05). Before coloration, Omnichroma showed the highest translucency values, while Clearfil Majesty ES-2 Universal showed the lowest. After 28 days of coloring, ZenChroma showed the highest. Conclusion: Translucency parameter of resin composites were significantly affected by the contents of the solutions, their coloring properties, and the content differences of the materials.en_US
dc.language.isoturen_US
dc.publisherAnkara Diş Hekimleri Odasıen_US
dc.relation.isversionof10.54617/adoklinikbilimler.1315465en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectTek renkli kompozit rezinen_US
dc.subjectSpektrofotometreen_US
dc.subjectTranslusensien_US
dc.subjectSingle-shade resin compositeen_US
dc.subjectSpectrophotometeren_US
dc.subjectTranslucencyen_US
dc.titleFarklı solüsyonlarla renklendirilen kompozit rezinlerin translusensi parametrelerinin değerlendirilmesien_US
dc.title.alternativeEvaluation of translucency parameters of resin composites colored with different solutionsen_US
dc.typearticleen_US
dc.contributor.departmentİstanbul Kent Üniversitesi, Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.authorIDhttps://orcid.org/0000-0003-2979-6068en_US
dc.contributor.authorIDhttps://orcid.org/0000-0003-3379-4567en_US
dc.contributor.institutionauthorKopuz, Dilan
dc.contributor.institutionauthorErçin, Özlem
dc.identifier.volume13en_US
dc.identifier.issue2en_US
dc.identifier.startpage296en_US
dc.identifier.endpage302en_US
dc.relation.journalADO Klinik Bilimler Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster