Evaluation of surface and positional trueness of removable dies fabricated through fused filament fabrication

dc.contributor.authorÇakmak, Gülce
dc.contributor.authorDönmez, Mustafa Borga
dc.contributor.authorErsöz, Ece
dc.contributor.authorDiken Türksayar, Almira Ada
dc.contributor.authorArınç, Hakan
dc.contributor.authorAdalı, Ufuk
dc.contributor.authorYılmaz, Burak
dc.contributor.authorPieralli, Stefano
dc.date.accessioned2026-03-04T10:59:18Z
dc.date.issued2026
dc.departmentİstanbul Kent Üniversitesi, Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.description.abstractObjectives: To evaluate the surface and positional trueness of removable dies fabricated using fused filament fabrication (FFF), compared to dies produced with digital light processing (DLP), addressing the limited evidence on the deviations of FFF-based removable dies. Methods: A typodont with a prepared right mandibular first molar was digitized to design a removable die and corresponding hollow partial arch cast. Forty dies (n = 10) and four casts (n = 1) were fabricated using FFF (Filadent Aligner [FF-AL], Filadent Gypsum [FF-GP], Filadent Tray [FF-TR]) or DLP (DentaModel [DM]). Dies and their positions in the casts were digitized to assess surface (crown, root, root base, overall) and positional (crown region and point-based) deviations. Data were analyzed either with one-way analysis of variance (surface deviations) or Kruskal-Wallis tests (positional deviations, α = 0.05). Results: DM exhibited the lowest crown region and overall deviations, followed by FF-TR (P < 0.001). Root deviations increased in the order of DM, FF-TR, FF-AL, and FF-GP, whereas FF-TR had the lowest base of the root deviations (P < 0.001). Seated FF-GP dies had lower crown region deviations than the other FFF-based dies, while DM led to lower deviations than FF-TR (P ≤ 0.041). FF-AL showed lower point-based deviations than FF GP (P = 0.001). Conclusions: FFF-fabricated dies showed lower surface trueness than DM dies, with FF-TR achieving the highest trueness among FFF dies. Positional deviations remained within clinically acceptable limits, though FF-TR dies tended to be positioned coronally and the others apically. FFF may be used to produce clinically acceptable dies, but DLP offers superior surface trueness. Clinical Significance: Removable dies produced with the tested polylactic acid filaments and FFF printer may serve as alternatives to those fabricated with the tested resin and vat polymerization printer, given the small and potentially clinically irrelevant differences in surface deviations and clinically acceptable mean positional deviations.
dc.identifier.citationÇakmak G., Dönmez MB., Ersöz E., Diken Türksayar AA., Arınç H., Adalı U., Yılmaz B., Pieralli S. Evaluation of surface and positional trueness of removable dies fabricated through fused filament fabrication. Journal of Dentistry, v.168, 2026, 106571.
dc.identifier.doi10.1016/j.jdent.2026.106571
dc.identifier.issn1879-176X
dc.identifier.orcid0000-0003-1751-9207
dc.identifier.orcid0000-0002-3094-7487
dc.identifier.orcid0000-0001-6331-454X
dc.identifier.orcid0000-0003-3558-3202
dc.identifier.orcid0000-0001-8675-648X
dc.identifier.orcid0000-0001-6557-2841
dc.identifier.orcid0000-0002-7101-363X
dc.identifier.orcid0000-0003-0061-8612
dc.identifier.scopus2-s2.0-105030836200
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0300571226002435?via%3Dihub
dc.identifier.urihttps://doi.org/10.1016/j.jdent.2026.106571
dc.identifier.urihttps://hdl.handle.net/20.500.12780/1404
dc.identifier.volume168
dc.identifier.wos001703615200001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFused filament fabrication
dc.subjectPositional trueness
dc.subjectRemovable die
dc.subjectSurface trueness
dc.titleEvaluation of surface and positional trueness of removable dies fabricated through fused filament fabrication
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
hakan.arinc
Boyut:
4.55 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: