• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Fakülteler
  • Diş Hekimliği Fakültesi
  • Klinik Bilimler Bölümü
  • Makale Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Fakülteler
  • Diş Hekimliği Fakültesi
  • Klinik Bilimler Bölümü
  • Makale Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

A comparison of the radiopacities of CAD-CAM restoratives: Effect of thickness

Tarih

2024

Yazar

Kopuz, Dilan
Arslan, Zeynep B.
Erçin, Özlem
Akar, Nevin K.
Tekçe, Neslihan

Üst veri

Tüm öğe kaydını göster

Künye

Kopuz D.; Arslan, Z. B.; Erçin, Ö.; Akar, N. K.; Tekçe, N. A comparison of the radiopacities of CAD-CAM restoratives: Effect of thickness (2024). American Journal of Dentistry, 7(4): 187-190.

Özet

PURPOSE: To evaluate the radiopacities of CAD-CAM materials using digital techniques. METHODS: Five different CAD-CAM materials were used (Cerasmart, LAVA Ultimate, Cerec Blocs C, Tetric CAD, and IPS e.max CAD) in this study (n= 5). For each group, samples with thicknesses of 1 and 2 mm were prepared. As a control, tooth slices with 1 and 2 mm thicknesses and a 99.5% pure aluminum step wedge were used. The samples, tooth slices, and step wedges were placed on a photostimulable phosphor plate. Radiographs were taken at 30 cm distance with 7 mA, 70 kVp, and 0.32 ms exposure time. The images were analyzed using the ImageJ software to measure the mean gray values. Data were analyzed with Kruskal-Wallis H test and the Mann-Whitney U test (P< 0.05). RESULTS: In the comparison of CAD-CAM materials with 1 and 2-mm thicknesses, the highest radiopacity value was seen in LAVA Ultimate samples (2.67 ± 0.05 for 1 mm samples: 5.74 ± 0.13 for 2 mm samples). The lowest value in 1 mm samples was seen in IPS e.max (0.59 ± 0.07), and in 2 mm samples, in Cerec Blocs C samples (1.49 ± 0.11). The results showed that the radiopacity values of the samples were associated with increased thicknesses. The 2 mm samples' radiopacity values were statistically significantly higher compared with the 1 mm samples. All samples except IPS e.max CAD and Cerec Blocs C had higher radiopacity than dentin (P< 0.05). CLINICAL SIGNIFICANCE: The radiopacity values were affected by thickness and type of materials. Comprehensive knowledge about the radiopacity of materials enables the selection of appropriate materials to achieve clinical success, which serves as a useful diagnostic aid in determining the long-term durability of restorations.

Kaynak

American Journal of Dentistry

Cilt

7

Sayı

4

Bağlantı

https://pubmed.ncbi.nlm.nih.gov/39186598/
https://hdl.handle.net/20.500.12780/887

Koleksiyonlar

  • Makale Koleksiyonu [120]
  • PubMed İndeksli Yayınlar Koleksiyonu [158]
  • Scopus İndeksli Yayınlar Koleksiyonu [301]
  • WoS İndeksli Yayınlar Koleksiyonu [268]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Kent

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber || Yönerge || Kütüphane || İstanbul Kent Üniversitesi || OAI-PMH ||

İstanbul Kent Üniversitesi, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
İstanbul Kent Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Kent:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.